EurOx.O2 G

Detektor tlenu O2
The "EurOx.O2 G" oxygen detectors are designed for use in stationary systems for the detection of decreasing or measuring oxygen concentrations in the air, outside explosive areas. For use with a wide range of control panels and controllers. Power supply 12 V DC.
Depending on the version, they can have different types of output :
- current : continuous (4-20mA), or dual threshold 4/8/12mA
- voltage outputs of OC type (NC or NO), two outputs signalling exceeding alarm thresholds Al1 and Al2.
- digital - RS485 connection, Modbus RTU protocol, addressable detector.
Sensors used : electrochemical, selective (measurement or dual threshold detection).
Detection of increase or decrease in O2 concentration.
Measuring range: 0-25% V/V. Alarm thresholds (standard) : 19/18 % V/V (decrease in O2 concentration) or 22/23 % V/V (increase in O2 concentration).
Visual indication on the detector of power supply, exceeding of alarm thresholds, failure .
PS plastic housing, cable entries (glands) : PG11 + PG9 (/RS485 versions only).
Areas of application : laboratories, sewage treatment plants, air quality control, chemical industry, etc.
Versions :
- EurOx.O2 G /E/D - detector with electrochemical sensor, A1/A2 alarm outputs type OC-NC or OC-NO
- EurOx.O2 G /E/S - sensor with electrochemical sensor, current output 4...20mA or 4/8/12mA
- EurOx.O2 G /E/RS485 - sensor with electrochemical sensor, RS485 output (Modbus RTU protocol)