eurOtox I2P
Mains supply ~230 V, maximum power consumption 15W.
Type of internal sensor (versions):
- O2 oxygen: electrochemical, selective, measuring range : 0-25 % V/V
- carbon monoxide CO: electrochemical, selective, measuring range : 0-500 ppm
- carbon dioxide CO2: infrared, selective, measuring range : 0-5 % V/V
- chlorine Cl2: electrochemical, selective, measuring range : 0-20 ppm
- Sulphur hexafluoride SF6: infrared, selective, measuring range : 0-2000 ppm
External detector connection
- external detector power supply : 12 V DC, max. 12 V DC, max. current consumption 250 mA
- Current input : (2) 4-20 mA , Rwe = 200 Ω
Alarm thresholds : 2 or 3, programmable alarm concentration levels (separately for internal and external detector).
Output type:
- relay (NO) : 3 outputs with programmable functions, max. load 3A/~230V
- Voltage : 2 outputs (WY-AL1, WY-AL2) with programmable functions, max. load 0.5A (total)
- RS485 (Modbus RTU protocol).
Detector functions:
- LCD display (visualisation of detector states, output states, configuration)
- 4-button keypad
- real-time clock
- event memory (1000 events)
- freely configurable inputs and outputs
- user-programmable control algorithm
- predefined configurations (factory settings)
- access protected by passwords.
Device versions:
- eurOtox O2 I2p/E/D/S/RS485 - O2 measurement detector (electrochemical sensor), relay outputs, RS485, 4-20mA output,
possibility to connect an external detector (4-20mA input)
- eurOtox CO I2p/E/D/S/RS485 - CO measurement detector (electrochemical sensor), relay outputs, RS485, 4-20mA output,
Possibility of connecting an external detector (4-20mA input)
- eurOtox CO2 I2p/E/D/S/RS485 - CO2 measuring detector (infrared sensor), relay outputs, RS485, 4-20mA output,
possibility to connect an external detector (4-20mA input)
- eurOtox Cl2 I2p/E/D/S/RS485 - Cl2 measuring detector (electrochemical sensor), relay outputs, RS485, 4-20mA output,
possibility to connect an external detector (4-20mA input)
- eurOtox SF6 I2p/E/D/S/RS485 - SF6 measuring sensor (infrared sensor), relay outputs, RS485, 4-20mA output,
possibility to connect an external detector (4-20mA input)